32 VELUX VELUX 33
2
1
PRG
max
5 sec
3
4
max 2 sec
max 2 sec
ENGLISH: Removing/adding electrical products connected to con-
trol unit KLC 500 from/to control keypad KLI 110
1
Disconnect all electrical products and reconnect only products to be
removed/added to control keypad KLI 110.
2
Remove/add control and transmit functions by pressing PRG button
in keypad for max 2 seconds. This procedure can take up to 2 min-
utes. LED flashes green slowly.
3
Remove cover from control unit. When LED in keypad flashes green
quickly, press test button in control unit for max 5 seconds to receive
system in the control unit and to transmit function of control unit.
4
When the first electrical product runs briefly back and forth, config-
ure the product(s) in the keypad by pressing any operation key for
max 2 seconds. LED flashes green slowly for a few seconds.
The product can now be controlled by control keypad KLI 110.
When configuration has been completed, LED is green for 4 seconds.
If configuration has failed, LED is red for 4 seconds.
Note: For electrical products controlled by a remote control KLR 100,
please refer to the user manual for KLR 100.
ESPAÑOL: Eliminar/añadir productos eléctricos conectados a la
unidad de control KLC 500 en el teclado de control KLI 110
1
Desconecte todos los productos eléctricos y reconectar solo los pro-
ductos que desea eliminar o añadir al teclado de control KLI 110.
2
Elimine/añada control y transmita las funciones presionando el botón
PRG en el teclado durante un máximo de 2 segundos. Este proce-
dimiento puede llevar hasta 2 minutos. El LED emite una luz verde
lentamente.
3
Quite la cubierta de la unidad de control. Cuando el LED del teclado
de control emita una luz verde rápidamente, presione el botón de
prueba de la unidad de control durante un máximo de 5 segundos
para que esta reciba señal del sistema y para transmitir las funciones
de la unidad de control.