Special roofing materials
66 VELUX
5
Roofing felt
Use flashing EDL/EBL/EKL for installation of VELUX roof windows
in roofs with roofing felt and a roof pitch steeper than 1. The
flashing must be positioned between the roofing felt layers with
correct overlaps which means that the order below must be
observed.
IN NEW ROOF
After having finished the boarding or sarking, and establishing
window aperture in roof, install the window.
1 Position bottom layer of roofing felt on the roof surface around
the window. Ensure that the roofing felt covers approx 50 mm of
the frame on all sides.
Note: Use a cold adhesive instead of naked flames that might
damage the window and the frame insulation collar from installa-
tion set BDX, if any.
2 Position top layer of roofing felt below the window – butt the
roofing felt to the bottom frame.
3 Fit flashing EDL. Distribute side soakers evenly along the sides of
the window.
4-5-6 Position top layer of roofing felt at top and sides of the
window.
IN EXISTING ROOF
Installation in existing roof follows the same principle as in new
roof with a few exceptions.
Cut hole in existing roong felt where the window is to be in-
stalled (see installation instructions) and install the window.
Position four strips of roong felt and lead it approx 50 mm up
the frame all the way round.
• Fit ashing EDL.
Position top layer of roong felt along sides and above window. It
is recommended to continue the roofing felt to the ridge to avoid
horizontal edges in the roofing felt.