Special roofing materials
72 VELUX
5
80 mm
X mm
Y + 45 mm
60-150 mm
30-60 mm
Min 270 mm
30-60 mm
Profiled metal sheets
If removing roofing sheets as shown on the previous pages is not
possible, use the following method.
Establish hole for window as shown.
Cut the metal sheets. The distance from the installation batten to
the metal sheet roof must be 80 mm. Extend the cut at least
270 mm on both sides of the window to make room for the entire
bottom flashing section.
Note that the end of the cut must finish on the highest level of the
roofing sheets.
The distance from the side frames to the metal sheet roof must be
30-60 mm. The distance from the top frame to the metal sheet
roof must be 60-150 mm.
Position the top flashing section under the metal sheets before
installing the window frame. Adjust foam gasket.