Special roofing materials
VELUX 77
A B
1 2
Slate
Use flashing EDL for installation of VELUX roof windows in slate
roofs.
A slate roof is tight because of the overlapping of the individual
slates. The required overlap depends on the roof pitch, local cli-
matic conditions etc.
When flashing a roof window in a slate roof, the flashing parts
must be fitted in such a way that they "replace" the slates that
were removed when the window was installed.
Therefore, when determining the position of the window in the roof,
the EDL bottom flashing section must be considered, ie it must be
flush with the slates thus "replacing" the slates removed (A).
If this is not possible, required overlap must be established in a
dierent way, eg by fitting an extension piece under the bottom
flashing section (B).
The EDL flashing is designed for slates with a thickness of up to
8 mm (1). By adjusting the side soakers, the flashing can be in-
stalled in slates with a thickness of up to 20 mm (2).
Special installation instructions (EDL+) are available, please contact
VELUX Company Ltd.